Y-Wall - Technical Overview

Modified on Fri, 8 Aug at 10:35 AM

Technical Overview - version 2023

RCM Y-Wall – Technical Overview Summary

  • Product: Calcium silicate sheathing board, BBA certified (14/5109).

  • Applications: Structural and non-structural sheathing behind façade/rainscreen cladding on steel or timber frames; internal lining in domestic/non-domestic buildings.

  • Fire Performance: Class A1 (BS EN 13501-1:2018).

  • Accredited Thicknesses: 9, 12, 15 mm.

  • Exposure: Suitable for all exposure zones; up to 1-year exposure if unprotected.

  • Thermal Conductivity: 0.23 W/mK.

  • Moisture Resistance: Class A – suitable for heat, high moisture, and severe frost (BS EN 12467:2018).

  • Durability: Passes hygrothermal and freeze-thaw testing to BS EN 12467.

  • Fixing: Mechanical fixing, withstands all wind loadings; no height limitations