Installation Guide - version 2025 - IN REVIEW
RCM Y-Wall – Installation Manual Summary
Product: High-quality calcium silicate fibre cement board for external sheathing (steel/timber frames) and internal lining; Class A1 fire rated.
Sizes: Thickness 6, 9, 12, 15 mm; standard board size 2400 × 1200 mm.
Fixings:
Steel frame – Ø4.8 × 38 mm FIX006 self-drilling winged screw.
Timber frame – Ø4.2 × 42 mm FIX005 self-drilling screw.
Max 300 mm spacing, min 12 mm from edge, 50 mm from corners.
Installation:
Store flat, dry, and protected.
Install smooth face outward, brick-bond pattern, 2–5 mm joint gaps.
Use EPDM tape at deflection joints, seal all joints and openings per fire strategy.
Cut on bench/trestles with dust suppression; use PPE for dust, noise, and vibration.
Jointing:
Non-fire-rated – Dafa UV tape + RCM Joint Seal liquid.
Fire-rated – add sealant in joints before taping.
Use EPDM or expanding tape at openings, movement joints, and concrete interfaces.
Applications: Fire-rated sheathing, ceilings, partitions, OEM uses; suitable for high-rise (>18 m).
Handling: Lift with long edges supported; avoid excessive flexing; follow site-specific QA procedures.